BUGSS Lab Notes – 8/1/16 Analysis of Prints from the Previous Lab Session: Our tests on 7/20/16 showed that increasing print time enabled us to print smaller posts. Increasing print time to 10 sec/layer  allowed us to print posts down to 150µm x 150µm in the x&y.  Looking at these prints under the microscope to determine the […]